Helping Medical professionals practice state of the art medicine affordably. Since 1983

New Whittemore 12-lead ECG workstation, PC based USB ECG Recorder

More Views

New Whittemore 12-lead ECG workstation, PC based USB ECG Recorder

New Call For Availability

Laptop Not Included


1. Compact and portable design for Recorder, with lead-off indicator light.
2. Real-time sampling, display and store mode, QRS wave analyzing in real-time, heart rate calculating and real-time printing, and provides multiple filter methods to avoid from baseline drift and interference.
4. ECG waveform is displayed using anti-aliasing technology clearly and intelligently, lead position can be adjusted, which solves the problem of overlapping waveform caused by baseline drift or high amplitude waveform.
5. High sampling frequency (1000Hz) ensures no distortion of ECG waveform. High resolution in display and printout guarantees the details of ECG waveform.
6. Provide dozens of sync and continuous display and print mode, including 6x2, 3x4, 3x4+2, etc. Auxiliary tool, such as superposed waveform analysis, electronic scale and editable terminology database, etc.,
7. Multiple analysis function, including: conventional 12-lead ECG, Frequency Cardiogram (FCG), High Frequency ECG, QT internal dispersion analysis, Heart Rate Variability (HRV) analysis, myocardium ischemia (STLE) analysis, Heart rate turbulence (HRT) analysis, Pacing ECG analysis, Vector Cardiogram (VCG), Time Vector Cardiogram (TVCG) and SAECG etc.
8. The "shortcut print" function can preview or print the whole analysis reports, and save them in PC with multimedia format (BMP, PNG, PDF or JPG format) according to factual need.
9. Support calling external procedures to obtain patient information of unknown origin, export HL7 aECG standard format ECG data, print electronic report and send notice to external procedure, convenience for systems docking with hospital HIS, PACS and others.



1-year manufacturer's warranty



Description

Details

Performance
HR display range: 30bpm~300bpm, error: 30bpm~100bpm, ±1bpm; 100bpm~ 300bpm, ±1%.
Sampling frequency: max. 1000Hz
Sampling accuracy: max. 24 bits
Lead: Standard 12 leads
Input loop current:≤ 0.1μA
CMRR: >60dB, >100dB (with filter)
Amplitude frequency characteristic: set 10Hz as benchmark, 0.05Hz~150Hz (-3dB~+0.4dB)
Noise level: ≤15μVp-p
Safety type: Class II Type CF with defibrillation protection

Accessories
Ground wire 1pc
ECG Workstation patch cord 2pcs
ECG Workstation data transmission line 1pc
ECG Workstation lead cable 1pc
Limb electrode clamp 1 set (4pcs)
Chest electrode 1 set (6pcs)
User manual 1pc