Electrosurgical

Buying an Electrosurgical Unit (ESU) for your Practice
We carry new and used/refurbished units, with various options to choose from depending on your needs.

 Thermocautery

The most basic machines are simple thermocautery units, burning the tissue to achieve hemostasis.

Such as: Disposable Cautery Pens.

 Electrocautery Devices

Monopolar/unipolar and bipolar electrocautery devices, not to be confused with electrosurgical units, are used to cauterize, coagulate, cut and desiccate (dry) tissue. A Hyfrecator is an example of such a unit, and uses a low power continuous spark to destroy tissue or stop bleeding during minor surgery. Other than small applications, such as skin tags, wart removal, hemostasis, etc., these devices are not intended for cutting tissue. No grounding plate is required.

 Bipolar electrocautery devices

The current between the two tips of a forcep thus reducing the risk of latent thermal energy. Available as stand-alone units and built into most major Electrosurgical Devices. This type of unit is used in ophthalmic, neurological, and laparoscopic procedures.

 Radiofrequency

Radiofrequency (RF) is a high frequency alternating electrical current that can be used in either bipolar or monopolar mode.

Built into the cutting mode  of most major Electrosurgical Devices for.

 The Elman is an example of a popular Radiofrequency device .

 Radiofrequency Ablation

Radiofrequency ablation (RFA), for arthroscopy, ENT, and gynecology, uses radio frequency to generate arcing through the bubbles formed between an active electrode and the tissue, with the tissue being vaporized by the arcing.  Examples of such dedicated generators include the Stryker Serfas, Smith & Nephew Dyonics Vulcan, as well as units by Arthrex and Mitek. 

 The new Velocity Orthopedics Velox™ Arthroscopy Wand achieves superior ablation at a lower power setting, using a basic electrosurgical generator - Velocity Orthopedics Velox™ Advanced Power Technology (APT).

 Electrosurgical Devices

Electrosurgical devices combine cutting, coagulation, electrocautery, electrosurgical, radiofrequency and alternating current (AC) to raise intracellular temperature in order to achieve tissue vaporization. Such devices have monopolar/unipolar and bipolar output and incorporate a grounding plate. Footswitches for the bipolar and cutting/coagulation functions are often offered as accessories.

 The most popular units accept a switching hand piece to go from cutting to coagulation with the push of a button.

 Systems vary in power output, from 50 to 400 watts. Lower power models are for minor, office-type procedures, and the higher output units are intended for major procedures.

Examples of electrosurgical devices include brands such as Bovie, Covidien, ValleyLab, and the Whittemore Eagle.

 Monopolar/unipolar usage incorporates a grounding plate.

 Newer models, such as the ValleyLab Force FX and the Whittemore Eagle, offer automatic impedance adjustment.

 Electrothermal Bipolar Vessel Sealing (EBVS)

Introduced in 1998, EBVS is an electrosurgical technology for sealing blood vessels up to 7mm in diameter. In addition to sealing blood vessels, modern instruments are designed to grasp and cut a variety of tissues.

 The ValleyLab Triad and Ligasure and the Whittemore Eagle models Two and Three combine vessel sealing functionality and a 400 watt electrosurgical system into one device, allowing for vessel sealing and bipolar electrocautery, as does a Triad.

 A Ligasure and the Eagle Two do vessel sealing as well as bipolar cutting.

 The Ligasure and the Triad only accept disposable instrumentation. The current Medtronic ForceTriad™ 2018 software prevents the reuse of disposable instruments.

 The Whittemore Eagle Three incorporates bipolar resection with saline, which allows surgeons to perform a variety of urological and gynecological procedures in a saline environment, as developed for the Olympus UES-40. The new ForceTriad™ offers a software upgrade to do bipolar resection with saline.

 Other energy platforms are available, such as the harmonic scalpel.

 Harmonic Scalpel

A harmonic scalpel cuts via vibration, with minimal energy transfer to the surrounding tissues. Using a harmonic scalpel may be superior to electrocautery in that it can cut through thicker tissue, creates less toxic surgical smoke, and may offer greater precision. However, it only coagulates as it cuts. An example is the Ethicon Ultracision.

 SMOKE EVACUATORS

 Surgical smoke is a potential hazard SMOKE EVACUATION SYSTEMS are used to reduce the risk of inhalation of surgical smoke.

 

Grid List

Set Descending Direction

1-20 of 123

Page:
  1. 1
  2. 2
  3. 3
  4. 4
  5. 5
  1. CONMED ARGON BEAM COAGULATOR 60-7550-120
    Used

    Configuration: Solid State, Isolated Output
    Frequency: 461 kHz (Cut, Blend, Pin Point Coag and Bipolar), 420 kHz (Spray Coag), 570 kHz (ABC® Technology)
    RF Isolation: <150mA per IEC 60601-2-2
    Input: 115V (± 10% at 60Hz 12.5A), 230V (± 10% at 50Hz 6.25A), 100V (± 10% at 50/60Hz 15A)
    Cooling: Convection (No fan)
    Dimensions: 24”Wx25”Dx41”H, 110 lbs (60.1cmWx63.5cmDx104.1cmH, 49.9kg), without cylinders
    Argon Gas Recommendations: 99.9985% purity
    Gas Flow: 0.1 SLPM - 10.0 SLPM

    Product Specifications

    ModeMaximum Power (Watts)Typical Open Circuit Vol. (PP V)Load (Ohms)
    Pure CUT 300 1,700 500
    Blend 3 200 2,000 500
    Blend 6 200 2,600 500
    Blend 9 200 3,400 500
    Spray COAG 80 9,200 500
    Pin Point COAG 120 4,800 500
    ABC® 150 12,000 500
    Bipolar COAG 70 300 100
    Learn More
  2. WHITTEMORE EAGLE 100 WATT MONOPOLAR + BIPOLAR ESU (VETERINARY & INTERNATIONAL USE ONLY)
    New

    MONOPOLAR AUTOCUT :
    Pure Sine wave 390 kHz
    Sp Cut - Programmable Pulse or continues output,
    200 W at 300 Ω, CF 1.5
    Pure   -  Continues output, 200 W at 300 Ω, CF 1.5
    Blend -  Bursts repeating at 29 kHz 55% ON cycle,
    120 W at 300 Ω, CF 2.5

    BIPOLAR :
    Pure Sine wave 390 kHz
    Micro - Lower output voltage, 50 W at 100 Ω, CF 1.5
    Macro - Higher output voltage, 50 W at 100 Ω, CF 1.5

    MONOPOLAR COAG:
    Damped Sine wave 460 kHz
    Soft - Repetition Frequency 62 kHz, 80 W at 500 Ω, CF 5.0
    Fulgurate - Repetition Frequency 34 kHz, 80 W at 500 Ω, CF 7.0
    Spray - Randomized Repetition Frequency 34 kHz < f < 50 kHz, 80 W at 500 Ω, CF 8.0

    DESIGN STANDARD:
    Classification according to the EC- Directive 93/ 42/ EEC: Class IIb
    General Safety Standards: IEC 60601-1-1, IEC 60601-2-2
    EMI/EMC Compatibility Standard: IEC 60601-1-2
    IS Safety Standard: IS 7583

    LEAKAGE CURRENTS
    • RF leakage current   • Monopolar : < 150 mA rms                         
                           • Bipolar : < 60 mA rms                          
    •  Low frequency leakage currents
           • Normal polarity, intact ground : < 10 μA  
           • Normal polarity, ground open : < 50 μA
          
    PREM SYSTEM
    Measuring Frequency : 85 kHz ± 10 kHz
    Measuring current : < 10 μA
    Acceptable Resistance Range up to 40%
               Dual Area PREM Patient Return Electrode : 5-135 Ω(Adaptive)
               Single Area Patient Return Electrode : < 10 Ω

    FEEDBACK SYSTEM  
    •  3 Microprocessor Controlled 6SENSE Technology
        with sampling rate above 4000 sense/second
    •  Maximum output power deviation < 15% or 5 watts,
        whichever is greater at any setting with PER-98
        
    INPUT POWER
    Operating Voltage : 180-265 Volt AC, (other ratings available on request)
    Max. Power input : 1000 VA,  Fuse : 4 A, UPS Backup : 1KVA
    DIMENSIONS
    L x W x H in cm - 38.0 x 30.5 x 11.5,          Weight in kg < 5.0

    6SENSE Technology : Maintain set power over wider range of tissue by Tissue Feedback Technology.
    PREM : Patient Return Electrode Monitoring - Safety against the Patient Return Electrode site burns.
    Randomized SPRAY Coag : Homogeneous, superficial, faster Coagulation over larger area.
    Self Diagnosis : Ensure the ESU with accessories are safe for functioning & display Error Codes if any.
    Bipolar Cut : Macro mode can be used for bipolar cutting with hooks and other cutting devices.
    Upgradability : Argon Beam Coagulation, Ultrasonic Aspirator, Smoke Evacuator, Suction Irrigation module.
    User Programmable : ONE Surgical Programs help in setting the system after power ON.
    Remote Power Settings :  Change mode and power from sterile field by normal Handswitch Pencil.
    Soft/Desiccate Coag : Faster cutting with coagulation for thicker tissues & soft coagulation.
    Foot Switches / Pedals : Explosion Proof (Fire Resistance) and Water Proof Foot Pedals
    Time Out Function (Optional) :  Automatically stops the HF output if prolong unintended activation.
    Surgical Applications  :  Useful for wide range of  surgical application as : Plastic, Neuro, ENT, Spine,
    Opthal, Laparo Surgery, Endo, GI, Ortho, Open & General Surgery, Onco, Gynecology, Hernia,
    GI Endocut, Papillotomy, Polypectomy, Under Water, Urology, Gynec TCRE, Hysteroscopy, Thoracotomy,
    Thoracic and Cardiac Surgery. Unit is suitable for all kind of Open, Endoscopic, Laparoscopic and Minimally
    Invasive Surgery  

    Learn More
  3. WHITTEMORE EAGLE ONE PREMIUM 300 WATT MONOPOLAR + BIPOLAR ESU (VETERINARY USE ONLY)
    New

    Monopolar AutoCut : Pure Sine wave 390 kHz
    Sp Cut - Programmable Pulse or continues output,
             300 W at 300 Ω, CF 1.5
    Pure - Continues output, 300 W at 300 Ω, CF 1.5
    Blend - Bursts repeating at 29 kHz 55% ON cycle,
            200 W at 300 Ω, CF 2.5
                
    Monopolar Coag : Damped Sine wave 460 kHz
    Soft - Repetition Frequency 62 kHz, 120 W at 500 Ω, CF 5.0
    Fulgurate LCF - Repetition Frequency 42 kHz, 120 W at 500 Ω, CF 6.2
    Fulgurate HCF- Repetition Frequency 34 kHz, 120 W at 500 Ω, CF 7.0
    Spray - Randomized Repetition Frequency 34 kHz < f < 50 kHz, 120 W at 500 Ω, CF 8.0

    Bipolar : Pure Sine wave 390 kHz
    Micro - Lower output voltage, 70 W at 100 Ω, CF 1.5
    Standard - Medium output voltage, 70 W at 100 Ω, CF 1.5   
    Macro - Higher output voltage, 70 W at 100 Ω, CF 1.5  

    DESIGN STANDARD
    Classification according to the EC- Directive 93/ 42/ EEC: Class IIb
    General Safety Standards: IEC 60601-1-1, IEC 60601-2-2
    EMI/EMC Compatibility Standard: IEC 60601-1-2
    IS Safety Standard: IS 7583

    LEAKAGE CURRENTS
    • RF leakage current   • Monopolar : < 150 mA rms                         
                           • Bipolar : < 60 mA rms                          
    •  Low Frequency leakage currents
                   • Normal polarity, intact ground : < 10 μA   
                   • Normal polarity, ground open : < 50 μA
                   
    PREM SYSTEM
    Measuring Frequency : 85 kHz ± 10 kHz
    Measuring current : < 10 μA
    Acceptable Resistance Range up to 40%
    Dual Area PREM Patient Return Electrode : 5-135 Ω (Adaptive)
    Single Area Patient Return Electrode : < 10 Ω

    FEEDBACK SYSTEM  
    •  3 Microprocessor Controlled 6SENSE Technology
        with sampling rate above 4000 sense/second
    •  Maximum output power deviation < 15% or 5 watts,
        whichever is greater at any setting with PER-98
        
    INPUT POWER
    Operating Voltage : 180-265 Volt AC, (other ratings available on request)
    Max. Power input : 1000 VA,  Fuse : 4 A, UPS Backup : 1.5KVA
    DIMENSIONS
    L x W x H in cm - 45.0 x 35.5 x 11.5,       Weight in kg < 7.5

    SENSE Technology : Maintain set power over wider range of tissue by Tissue Feedback Technology.
    PREM : Patient Return Electrode Monitoring - Safety against the Patient Return Electrode site burns.
    2SiCoag : Two Simultaneous coagulation output at a time with independent control.
    Randomized SPRAY Coag : Homogeneous, superficial, faster coagulation over larger area.
    Self Diagnosis : Ensure the ESU with accessories are safe for functioning & display Error Codes if any.
    Bipolar Cut : Macro mode can be used for bipolar cutting with hooks and other cutting devices.
    Upgradability : Argon Beam Coagulation, Ultrasonic Aspirator, Smoke Evacuator, Suction Irrigation module.
    User Programmable : THIRTY Surgical Programs help in setting the system after power ON.
    BiCoag Alarm : Audio feedback after completion of Bipolar Coag, reduces charring and sticking.
    Pulse Cut : Tissue feedback Pulse Interval controlled Pulse Cut for Polypectomy & Papillotomy.
    AutoBip : Automatic Start & Stop of Bipolar current by tissue sensing without foot switch activation.
    Remote Power Settings : Change mode and power from sterile field by normal Handswitch Pencil.
    Foot Switches / Pedals : Explosion Proof (Fire Resistance) and Water Proof Foot Pedals
    Time Out Function (Optional) :  Automatically stops the HF output if prolong unintended activation.
    Surgical Applications  :  Useful for wide range of  surgical application as : Plastic, Neuro, ENT, Spine,
    Opthal, Laparo Surgery, Endo, GI, Ortho, Open & General Surgery, Onco, Gynecology, Hernia,
    GI Endocut, Papillotomy, Polypectomy, Under Water, Urology, Gynec TCRE, Hysteroscopy, Thoracotomy,
    Thoracic and Cardiac Surgery. Unit is suitable for all kind of Open, Endoscopic, Laparoscopic and Minimally
    Invasive Surgery 

    Learn More
  4. Whittemore Eagle Two Veterinary Advanced Vessel Seal + Bipolar Generator
    New

    Whittemore Eagle Two Advanced Vessel Sealing Generator with following features:
    5 Inch touch screen
    • Vessel Sealing Mode seals tissue up to 7mm like that of the ValleyLab Ligasure with audio indication stops at completion of seal! 6SENSE Technology is recent innovation in field of advance feedback controlled Electrosurgical Technology. System senses the tissue hold in instrument & appropriate amount of energy is delivered by continually sensing the tissue density to form the permanent seal.
    • Cool Seal- Innovative technology to seal the tissue vessel by applying calibrated pressure with RF energy. The Collagen & Elastin within the tissue in vessel walls melts & restructure to form a seal. The seal tissue appears translucent in nature & having plastic resistance property.
    • Sealing Program auto-select is available as per the selected accessory & grasped tissue.
    • Seal Mode : Level 1 to Level 5, 440 khz 150 W
    • Bipolar Mode 100 W, at 100 Ohms   
    • Auto Stops the energy delivery with audio indication at completion of sealing cycle.
    • Tissue ReHold alarm is given if improper grasping of tissue.
    • Bipolar with independent Display setting with independent foot- switches for all Bipolar laparoscopy instrument.
    • Reusable Attachments for Lapro & open Sealer.
    • Bipolar Cut & Coag : Bipolar Cut & Coag Mode with independent settings and activation.
    • CE Mark Product & ISO 9001 & ISO13485 Certified Company
    Comes with the following  
    Standard accessories :
     Mains Cable
     Footswitch Single Paddle
     Footswitch Double Paddle
     Sealing Forcep 
     Cable for Sealing Forcep
    180-265V 50-60 Hz
     Size 15X12 X5 INCH

    Optional - Sealer divider

    Learn More
  5. Whittemore Eagle Two Plus Veterinary Vessel Sealing Unit
    New

    THE EAGLE TWO PLUS OFFERS 
    Vessel Sealing,  Cutting and Coagulation with switching Pencil and Bipolar

    One Touch : Touch screen 5.7” TFT panel operation for flexible use
    Self Demonstration Mode : System gives self demonstration and settings for users
    User Programmable : 100 user settable programs with case names helps in setting the system
    Recall Function : Automatic last status resume
    1 Monopolar -Dual Monopolar Mode (Optional) : Independent power and mode setting for two Monopolar channel
    1 Coag - Dual (Optional): Two Simultaneous coagulation output at a time with independent control.
    Bipolar Cut & Coag : Bipolar Cut & Coag Mode with independent settings and activation.
    BiCoag Alarm : Audio feedback after completion of Bipolar Coag, reduces charring and sticking.
    Dual Vessel Sealing :  Vessel Sealing up to 7mm with reusable Open & Lapro attachments.
    Auto Stops : the energy delivery with audio indication at completion of sealing.
    Tissue ReHold alarm is given if improper grasping of tissue.
    2 Endo Mode : Tissue feedback Pulse Interval controlled Pulse Cut for Polypectomy & Papillotomy.
    Argon Beam Coagulator upgradable : ESU can be upgraded for Argon Beam Coagulation module.
    SENSE Technology : Maintain set power over wider range of tissue by Tissue Feedback Technology.
    PREM : Patient Return Electrode Monitoring - Safety against the Patient Return Electrode site burns.
    Self Diagnosis : Ensure the ESU with accessories are safe for functioning & display Error Codes if any.

    7 Cut Modes:

    Low Cut : 400 W
    Pure Cut : 400 W
    Blend 1 Cut : 250 W
    Blend 2 Cut : 200 W
    Endo 1: 400 W
    Endo 2: 400 W
    Hydro : 400 W

    6 Coag Modes:

    Soft: 300 W
    Desiccate : 150 W
    Swift : 120 W
    Fulgurate: 120 W
    Spray Coag : 120 W
    Hydro: 120 W

    2 Bipolar Cut Modes:

    Macro Bip: 95 W
    Bipolar Cut : 95 W
    3 Bipolar Coag Modes:  

    Micro Bip: 95 W
    Standard: 95 W
    Force : 95 W

    2 Vessel Seal Modes: 

    Micro Seal: Level 1(80W) to Level 5(150W)
    Standard Seal: Level 1(80W) to Level 5(150W)
     
    ESU Applications:
    • Gynecology • Laproscopic Surgeries • Endoscopy ( ERCP) • Oncosurgery • Heart & Chest surgery, CABG •Neurosurgery, Spine • Arthroscopy • All other general surgical procedures.

    Vessel Sealer Applications:
    • Abdominal Hysterectomy (Spay)• Adrenalectomy • Colectomy • Colon Resection • Cystectomy • Gastrectomy • Gastric Bypass • Hemorrhoidectomy • Lap-Assisted Vaginal Hysterectomy (LAVH) • Lap-Cholecystectomy • Liver Resection • Nephrectomy • Nissen Fundoplication • Radical Hysterectomy • Radical Prostatectomy • Splenectomy • Salpingo-oophorectomy • Vaginal Hysterectomy • Whipple

    INCLUDES:
    SEALING FORCEP
    CABLE FOR SEALING CLAMP
    SILICONE PATIENT RETURN PLATE
    CORD FOR PATIENT RETURN PLATE
    BIPOLAR FORCEPS  STRAIGHT 20CM 1MM TIP
    CORD FOR BIPOLAR FORCEPS
    MONOPOLAR HANDSWITCHING PENCIL REUSABLE
    FOOTSWITCHING CHUCK HANDLE
    UNIVERSAL ADAPTOR
    SET OF ELECTRODES:
    Needle Electrode
    Blade Electrode
    Ball Electrode

    Learn More
  6. WHITTEMORE EAGLE THREE HIGH PERFORMANCE 400 WATT ESU WITH VESSEL SEALING SYSTEM & SALINE PLASMA  BIPOLAR RESECTION, IN SINGLE UNIT. (VETERINARY USE ONLY)
    New

    COMBO Generator Technology: High Performance ESU (Diathermy) with Vessel Sealing System & Saline Plasma  Bipolar Resection, in Single Unit.

    One Touch : Touch screen 7” TFT panel operation for flexible use
    Internet Enabled : Remote programmable / calibration
    Data Logging : Last 50 surgical cases data stored in system memory
    Self Demonstration Mode : System gives self demonstration and settings for users
    User Programmable : 100 user settable programs with case names helps in setting the system
    Recall Function : Automatic last status resume
    Auto Mode : Auto mono & bipolar mode for without foot / hand activation
    Dual Mono Mode : Independent power and mode setting for two Monopolar channel
    2SiCoag : Two Simultaneous coagulation output at a time with independent control.
    Bipolar Cut & Coag : Bipolar Cut & Coag Mode with independent settings and activation.
    BiCoag Alarm : Audio feedback after completion of Bipolar Coag, reduces charring and sticking.
    Dual Vessel Sealing : Two Channel Vessel Sealing up to 7mm with reusable Open & Lapro attachments.
    Auto Stops : the energy delivery with audio indication at completion of sealing.
    Tissue ReHold alarm is given if improper grasping of tissue.
    Saline Resection : Bipolar Saline Plasma Cut two modes & Coag two modes.
    Saline Safety Alarm : Electrode Disconnection / Non Saline activation Alarm.
    Cost Effective Saline use : Regular Working Element can be used with regular loops.
    2 Endo Mode : Tissue feedback Pulse Interval controlled Pulse Cut for Polypectomy & Papillotomy.
    Argon Beam Coagulator up-gradable : ESU can be upgraded for Argon Beam Coagulation module.
    SENSE Technology : Maintain set power over wider range of tissue by Tissue Feedback Technology.
    PREM : Patient Return Electrode Monitoring - Safety against the Patient Return Electrode site burns.
    Self Diagnosis : Ensure the ESU with accessories are safe for functioning & display Error Codes if any.

    7 Cut Modes:
    Low Cut : 400 W
    Pure Cut : 400 W
    Blend 1 Cut : 250 W
    Blend 2 Cut : 200 W
    Endo 1: 400 W
    Endo 2: 400 W
    Hydro : 400 W

    6 Coag Modes:
    Soft: 300 W
    Desiccate : 150 W
    Swift : 120 W
    Fulgurate: 120 W
    Spray Coag : 120 W
    Hydro: 120 W

    2 Bipolar Cut Modes:
    Macro Bip: 95 W
    Bipolar Cut : 95 W

    3 Bipolar Coag Modes:  
    Micro Bip: 95 W
    Standard: 95 W
    Force : 95 W

    2 Vessel Seal Modes:
    Micro Seal: Level 1(80W) to Level 5(150W)
    Standard Seal: Level 1(80W) to Level 5(150W)

    2 Saline Plasma Bipolar Cut Modes:
    Saline Low: 300 W
    Saline Standard : 300 W

    2 Saline Plasma Bipolar Coag Modes:
    Saline Low: 300 W
    Saline Standard : 300 W
     
    ESU Applications:
    • Gynecology • Laproscopic Surgeries • Endoscopy ( ERCP ) • Oncosurgery • Heart & Chest surgery, CABG •Neurosurgery, Spine • Arthroscopy • All other general surgical procedures.

    Vessel Sealer Applications:
    • Abdominal Hysterectomy • Adrenalectomy • Appendectomy • Colectomy • Colon Resection • Cystectomy • Gastrectomy • Gastric Bypass • Hemorrhoidectomy • Lap-Assisted Vaginal Hysterectomy (LAVH) • Lap-Cholecystectomy • Liver Resection • Nephrectomy • Nissen Fundoplication • Radical Hysterectomy • Radical Prostatectomy • Splenectomy • Salpingo-oophorectomy • Vaginal Hysterectomy • Whipple

    Saline Plasma Resection Applications:
    • TCRE • Hysteroscopy • TCRE • Arthroscopic surgery

    INCLUDES:
    SEALING FORCEP
    CABLE FOR SEALING CLAMP
    SILICONE PATIENT RETURN PLATE
    CORD FOR PATIENT RETURN PLATE
    BIPOLAR FORCEPS  STRAIGHT 20CM 1MM TIP
    CORD FOR BIPOLAR FORCEPS
    MONOPOLAR HANDSWITCHING PENCIL REUSABLE
    FOOTSWITCHING CHUCK HANDLE
    INIVERSAL ADAPTOR
    SET OF ELECTRODES:
    Needle Electrode
    Blade Electrode
    Ball Electrode

     

    Learn More
  7. WHITTEMORE EAGLE SALINE TURP INSTRUMENT SET
    New

    Whittemore Bipolar Saline working element with isolated CFR sheath

     

    Learn More
  8. WHITTEMORE EAGLE REUSABLE 10MM VESSEL SEALING DIVIDER INSTRUMENT
    New

    THE EAGLE 2 AND 3 10MM Sealer divider
    10MM Vessel Sealing with Cutting blade.

    Sealer Handle, 10mm with cable
    Sealer Insert, Straight, Dia 10mm, 32 cm Also available in 9 cm
    Blade 10mm (Pack of 10 blades)

    • Abdominal Hysterectomy (Spay)• Adrenalectomy • Colectomy • Colon Resection • Cystectomy • Gastrectomy • Gastric Bypass • Hemorrhoidectomy • Lap-Assisted Vaginal Hysterectomy (LAVH) • Lap-Cholecystectomy • Liver Resection • Nephrectomy • Nissen Fundoplication • Radical Hysterectomy • Radical Prostatectomy • Splenectomy • Salpingo-oophorectomy • Vaginal Hysterectomy • Whipple

     

    Learn More
  9. WHITTEMORE EAGLE 5MM BIPOLAR VESSEL SEALER
    New

    5MM Vessel Sealing

    Sealer Handle, 5mm
    Sealer Insert, Straight OR Maryland, Dia 5mm, 32 cm Also available in 18 cm

    • Adrenalectomy • Appendectomy • Colectomy • Cystectomy• Gastrectomy • Gastric Bypass • Lap-Assisted Vaginal Hysterectomy (LAVH) • Lap-Cholecystectomy • Liver Resection • Nephrectomy • Nissen Fundoplication • Splenectomy • Salpingo-oophorectomy • Adrenalectomy • Appendectomy • Colectomy • Cystectomy• Gastrectomy • Gastric Bypass • Lap-Assisted Vaginal Hysterectomy (LAVH) • Lap-Cholecystectomy • Liver Resection • Nephrectomy • Nissen Fundoplication • Splenectomy • Salpingo-oophorectomy

     

    Learn More
  10. WHITTEMORE EAGLE  OPEN PROCEDURE VESSEL SEALING INSTRUMENT
    New

    THE EAGLE 2 AND 3 Open Procedure Sealer

    • Abdominal Hysterectomy (Spay)• Adrenalectomy • Colectomy • Colon Resection • Cystectomy • Gastrectomy • Gastric Bypass • Hemorrhoidectomy •Hysterectomy (LAVH) • Liver Resection • Nephrectomy • Nissen Fundoplication • Radical Hysterectomy •  Splenectomy • Salpingo-oophorectomy •  Whipple

     Available in Coated or Non Coated

    Learn More
  11. Reusable Switching Handpiece for ESU
    New
    Reusable Switching Handpiece for ESU Learn More
  12.  Disposable Switching Handpiece for ESU
    New
    Disposable Switching Handpiece for ESU Learn More
  13. WHITTEMORE ESU ACCESSORY PACK
    New

    SEALING FORCEP
    CABLE FOR SEALING CLAMP
    SILICONE PATIENT RETURN PLATE
    CORD FOR PATIENT RETURN PLATE
    BIPOLAR FORCEPS  STRAIGHT 20CM 1MM TIP
    CORD FOR BIPOLAR FORCEPS
    MONOPOLAR HANDSWITCHING PENCIL REUSABLE
    FOOTSWITCHING CHUCK HANDLE
    UNIVERSAL ADAPTOR
    SET OF ELECTRODES:
    Needle Electrode
    Blade Electrode
    Ball Electrode

    Learn More
  14. Esu Patient plate photo
    New

    Reusable 5" x 7" dispersive patient plate with one cable

    Valley Lab - Banana Jack or Stereo Connector -

    Please tell us what your electrosurgical unit takes

    Learn More
  15. Patient Plate Wire with Valleylab Plug
    New

    PATIENT PLATE WIRE WITH VALLEY LAB PLUG

    (When selling wire separately)

    Learn More
  16. Force Triad
    Used
    VALLEYLAB FORCE TRIAD ESU SYSTEM

    - THREE TOUCH SCREEN LEDS
    - CUT: 660 Hz
    - VALLEYLAB: 800 Hz
    - COAG: 940 Hz
    - BIPOLAR: 940 Hz
    - LIGASURE: 440 Hz

    INCLUDES:
    - TRIAD CONSOLE
    - E6019 BIPOLAR FOOTSWITCH
    - LS0300 LIGASURE FOOTSWITCH
    - TWO-PEDAL MONOPOLAR FOOTSWITCH
    - FT6003 MONOPOLAR FOOTSWITCH
    Learn More
  17. picture of valleylab ligasure vessel sealing system
    Used

    Valleylab Ligasure Vessel Sealing System
    generator, bipolar only

    designed to permanently seal vessels
    and tissue bundles

    features:
    - vessel sealing technology
    - instant response technology
    - bipolar cutting capability

    specifications
    - output waveform:
    macrobipolar/bipolar: 473 khz
    sinusoid, 100% duty cycle
    seal: 473 khz sinusoid, pulsed
    - ouput: isolated
    - cooling: natural convection
    - display: two 0.75in digital seven segment
    - mounting: cart or flat surface
    - overall dimensions: 15in w x 16 in d x 5in h
    - weight: 1 lb

    includes footswitch

    LS1500 Sealer / Divider. $400.00 

    Learn More
  18. picture of valleylab ls3090 ligasure max reusable
    Used

    Valleylab LS2070 Ligasure Reusable Forcep
    - handswitching open instrument
    - 7in  curve 30° jaw
    - used with snap-in electrode ls3092

    Learn More
  19. Valleylab Ls3110 Ligasure Xtd Reusable
    Used
    VALLEYLAB LS3110 LIGASURE XTD REUSABLE
    FORCEP

    - HANDSWITCHING OPEN INSTRUMENT
    - 11in (28cm), CURVED 30° JAW
    - USED WITH SNAP-IN ELECTRODE LS3111
    Learn More
  20. picture of valleylab force fx electrosurgical unit
    Used

    Valleylab Force Fx Electrosurgical Unit
    cut-300 watts
    blend-200 watts
    coag-120 watts
    bipolar-70 watts
    3 bipolar modes: precise, standard,
    macro
    3 monopolar cut modes: low, pure,
    blend
    3 monopolar coag modes: desiccate,
    fulgurate, spray
    2 monoplar jacks: mono 1 and 2

    Learn More

Grid List

Set Descending Direction

1-20 of 123

Page:
  1. 1
  2. 2
  3. 3
  4. 4
  5. 5