New Whittemore Enterprises digital touch screen 12-channel 12-lead ECG EKG

New Whittemore Enterprises digital touch screen 12-channel 12-lead ECG EKG

New Call For Availability

8"TFT Color LCD shows the working status and ECG waveform. Check the waveform before printing to save record paper.
12 Leads ECG simultaneous  digital signal processing,  AC, DFT and EMG filtering of the ECG signals.
Simultaneous display of 3/6/12 leads ECG waveform, and the state of printing mode, sensitivity, speed, filter etc, for easy for diagnosis.
Multiply printing modes and formats, including 12*1, 6*2+1(rhythm lead), 6*2, rhythm 12, rhythm 10, rhythm 8, rhythm 6, manual and freeze, etc.
The instrument has the functions of auto-analysis and auto-diagnosis of regular ECG waveform parameters, provides measurement parameters such as HR, P-R interval, P Duration, QRS Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc and auto-diagnosis conclusion to reduce doctor's burden.
AC/DC power supply. Built-in rechargeable lithium polymer battery. Standby for 4 hours, print continually for 90 min, and print 150 pieces of ECG waveform.
Built-in MSF, can store more than 1000 cases.
System provides Chinese/English/Spanish/Turkish operation interface and can print multiply languages report.
System provides multiply printing speeds, including 5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s, and abstract conclusion graph printing.



1-year manufacturer's warranty



Description

Details

Environment conditions
   Operation
a) Environment temperature: +5degrees~+35℃
b) Relative humidity: ≤80%
c) Power supply: AC:100V~240V,50/60Hz
              DC:14.8V, 3700 mAh rechargeable lithium battery
d) Atmospheric pressure: 86kPa~106kPa
   Transportation and Storage
a) Environment temperature: -10℃~55℃
b) Relative humidity: ≤95%
c) Atmospheric pressure: 50kPa~106kPa
-Input way: Floating and defibrillation protection
-Lead: Standard 12 leads
-Patient leak current: <10µA
-Input impedance: ≥50MΩ
-Frequency response: 0.05Hz~150Hz(-3dB)
-Time constant: Time constant>3.2s
-CMRR: >60dB, >100dB( Adding filter)
-EMG interference filter: 35Hz(-3dB)
-Recording way: Thermal printing system
-Specification of recording paper: 210mm(W)*20m(L) high-speed thermal paper
-Paper speed:
 Auto record: 25mm/s, 50mm/s, error:±5%
 Rhythm record: 25mm/s, 50mm/s, error:±5%
 Manual record:5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s, error:±5%
-Sensitivity selections: 2.5,5,10,20,40mm/mV, error:±5%. Standard sensitivity is 10mm/mV±0.2mm/mV.
-Auto record: Record setup according to auto record format and mode, automatically changing leads, measuring and analysing.
-Rhythm record: record setup according to rhythm record format and mode, automatically measuring and analysing.
-Manual record: record setup according to manual record format, manually changing leads.
-Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P A*is, QRS A*is, T A*is, R(V5) , S(V1) , R(V5)+S(V1)
-Product safety type: Class I CF applied part; there is defibrillation and pacing protection circuit in it.
-Enduring polarization voltage: ±300mV
-Noise level: ≤15µVp-p
-Fuse specification: 2 pcs φ5*20mm AC time lag; T1.6A/250V(Power supply 220V)
-Size: 340mm(L)*320mm(W)*85mm(H)
-Net Weight: 3.2Kg