Helping Medical professionals practice state of the art medicine affordably. Since 1983

New Whittemore Portable one-channel 12-lead EKG electrocardiograph+ Printer

More Views

New Whittemore Portable one-channel 12-lead EKG electrocardiograph+ Printer

New Qty: 1

-2.7" FSTN display shows the working status and ECG waveform. Check the waveform before printing to save record paper.
-Output system:High-resolution thermal-array(32dots/mm),.Recording frequency Response:Up to 150Hz.
-The device can record exact single ECG waveform and remark. The mark includes:lead sign,ensitivity,paper speed,filter state.
- Under automatic mode,just press the button once,it starts record procedure,which can enhance your work efficiency
-The language of operation interface include include(Chinese,English,French,Italian,Turkish,Espanol,Deutsch,Russia)
- Classification:Class:I,CF defibrillator proof
- Power supply:AC/DC,rechargeable lithium battery inside.
- Can record 160 pieces of ECG waveform and 4hours, standby for 10 hours continually on battery
Technical Specification:
Normal work environment
a. Environment temperature: +5℃~+35℃
b. Relative humidity: ≤80%
c. Atmospheric pressure: 86kPa~106kPa
Store and Transportation
a. Environment temperature: -10~55℃
b. Relative humidity: ≤95%
c. Atmospheric pressure: 50kPa~106kPa
ECG instrument input
-Input way: Floating and defibrilation protection
-Lead: Standard 12 leads
-Patient leak current: <10μA
-Sampling rate:1000Hz
-A/D change:10 Bit
-Frequency response: 0.05Hz~150Hz(-3dB,+0.4dB)
-Time constant: Time constant>3.2s
-CMRR: >60dB, >100dB( With AC filter)
-Enduring polarization voltage:±500mV
-Noise level: ≤15μVp-p
-EMG interference filter: 35Hz(-3dB)
-AC filter:50Hz/60Hz(≥20dB)
-Sensitivity choice: 5,10,20mm/mV, error:±5%.Standard sensitivity is 10mm/mV±0.2mm/mV
-Recording way: Thermal printing system
-Auto-record: according the the record format and auto-mode to set, auto leads-changing, auto measurement.
-Manual record: according the record format to record, manual leads-changing.
-Specification of recording paper:50mm(W) × 20mm(L)High-speed thermal paper
-Paper speed: 25mm/s,50mm/s,error:±5%
-Product safety type:Class I, type CF defibrillator proof
-Fuse Specification:2 pcs φ5*20mm AC time lag; T1.6AL250V
-Size:315mm(L)*215mm(W)*77mm(H)
-Net Weight:1.5kg
-Power supply: AC:100~240V,50/60 Hz
DC: 7.4V, 2000 mAh rechargeable lithium battery

Accessories:

    An ECG cable
    Disposable electrodes 1set
    ECG convert adapter  1set
    A thermal recording paper
    A power cord
    An earth wire
    A user manual


1-year manufacturer's warranty



Additional Information

Additional Information

NEW/USED New
SKU EKG-WE-1-CHANNEL
Power Requirements No
Manuals and Specs.