Electrosurgical
Buying an Electrosurgical Unit (ESU) for your Practice
We carry new and used/refurbished units, with various options to choose from depending on your needs.
Thermocautery
The most basic machines are simple thermocautery units, burning the tissue to achieve hemostasis.
Such as: Disposable Cautery Pens.
Electrocautery Devices
Monopolar/unipolar and bipolar electrocautery devices, not to be confused with electrosurgical units, are used to cauterize, coagulate, cut and desiccate (dry) tissue. A Hyfrecator is an example of such a unit, and uses a low power continuous spark to destroy tissue or stop bleeding during minor surgery. Other than small applications, such as skin tags, wart removal, hemostasis, etc., these devices are not intended for cutting tissue. No grounding plate is required.
Bipolar electrocautery devices
The current between the two tips of a forcep thus reducing the risk of latent thermal energy. Available as stand-alone units and built into most major Electrosurgical Devices. This type of unit is used in ophthalmic, neurological, and laparoscopic procedures.
Radiofrequency
Radiofrequency (RF) is a high frequency alternating electrical current that can be used in either bipolar or monopolar mode.
Built into the cutting mode of most major Electrosurgical Devices for.
The Elman is an example of a popular Radiofrequency device .
Radiofrequency Ablation
Radiofrequency ablation (RFA), for arthroscopy, ENT, and gynecology, uses radio frequency to generate arcing through the bubbles formed between an active electrode and the tissue, with the tissue being vaporized by the arcing. Examples of such dedicated generators include the Stryker Serfas, Smith & Nephew Dyonics Vulcan, as well as units by Arthrex and Mitek.
The new Velocity Orthopedics Velox™ Arthroscopy Wand achieves superior ablation at a lower power setting, using a basic electrosurgical generator - Velocity Orthopedics Velox™ Advanced Power Technology (APT).
Electrosurgical Devices
Electrosurgical devices combine cutting, coagulation, electrocautery, electrosurgical, radiofrequency and alternating current (AC) to raise intracellular temperature in order to achieve tissue vaporization. Such devices have monopolar/unipolar and bipolar output and incorporate a grounding plate. Footswitches for the bipolar and cutting/coagulation functions are often offered as accessories.
Systems vary in power output, from 50 to 400 watts. Lower power models are for minor, office-type procedures, and the higher output units are intended for major procedures.
Monopolar/unipolar usage incorporates a grounding plate.
Newer models, such as the ValleyLab Force FX and the Whittemore Eagle, offer automatic impedance adjustment.
Electrothermal Bipolar Vessel Sealing (EBVS)
Introduced in 1998, EBVS is an electrosurgical technology for sealing blood vessels up to 7mm in diameter. In addition to sealing blood vessels, modern instruments are designed to grasp and cut a variety of tissues.
The ValleyLab Triad and Ligasure and the Whittemore Eagle models Two and Three combine vessel sealing functionality and a 400 watt electrosurgical system into one device, allowing for vessel sealing and bipolar electrocautery, as does a Triad.
A Ligasure and the Eagle Two do vessel sealing as well as bipolar cutting.
The Ligasure and the Triad only accept disposable instrumentation. The current Medtronic ForceTriad™ 2018 software prevents the reuse of disposable instruments.
The Whittemore Eagle Three incorporates bipolar resection with saline, which allows surgeons to perform a variety of urological and gynecological procedures in a saline environment, as developed for the Olympus UES-40. The new ForceTriad™ offers a software upgrade to do bipolar resection with saline.
Other energy platforms are available, such as the harmonic scalpel.
Harmonic Scalpel
A harmonic scalpel cuts via vibration, with minimal energy transfer to the surrounding tissues. Using a harmonic scalpel may be superior to electrocautery in that it can cut through thicker tissue, creates less toxic surgical smoke, and may offer greater precision. However, it only coagulates as it cuts. An example is the Ethicon Ultracision.
Surgical smoke is a potential hazard SMOKE EVACUATION SYSTEMS are used to reduce the risk of inhalation of surgical smoke.
-
UsedEntec Arthrocare 08516 System 2000 Console
Learn More -
UsedBUFFALO FILTER PLUMESAFE WHISPER TURBO AS
SMOKE EVACUATION SYSTEM
MODEL: PSWTURBO AS
FEATURES:
- RFID (RADIO FREQUENCY IDENTIFICATION) FOR
CONSTANT COMMUNICATION TRACKING AND
CONTROL BETWEEN THE SYSTEM AND FILTER
- AUTO-SENSE FEATURE TRACKS AND DISPLAYS
THE EXACT NUMBER OF HOURS & MINUTES
REMAINING ON THE VIROSAFE FILTER
- TURBO POWER PROVIDES VERSATILITY
FROM LAPAROSCOPIC TO LARGE VOLUME
SMOKING PROCEDURES
- PORTABLE OR TABLETOP
- PNEUMATIC FOOTSWITCH INCLUDED
SPECIFICATIONS:
- MAXIMUM FLOW RATES:
1.38in (35mm) TUBING = 79 CFM / 2239 LPM
1.25in (32mm) TUBING = 68 CFM / 1923 LPM
0.88in (22mm) TUBING = 44 CFM / 1246 LPM
0.25in (6mm) TUBING = 5.2 CFM / 147 LPM
DIMENSIONS: 13.5in x 8in x 17in
WEIGHT: 13.75 lbs.
Learn More -
Used
-
Used
-
Used
-
Used
-
Used
ValleyLab E6008B Footswitch, Monopolar
Learn More
- Low Profile and Water Resistant Design
- Non-Skid Rubber Base
- Compatible With All Force Series Generators
- Dimensions: 7.5in x 8.6in x 2.25in
- Weight: 4.1lbs
- Cord Length: 10ft
*** SOLD WITH SYSTEM ONLY *** -
Used
VALLEYLAB E6009 FOOTSWITCH, BIPOLAR
Learn More
- STANDARD BIPOLAR FOOTSWITCH
- WATER RESISTAND DESIGN
- NON-SKID RUBBER BASE
- COMPATIBLE WITH ALL FORCE SERIES GENERATORS
- DIMENSION: 4.6 X 3.5 X 1.8 INCHES
- WEIGHT: 1.7 LBS.
- 10FT CORD LENGTH
- SOLD WITH SYSTEMS -
Used
ValleyLab E6008 Footswitch, Monopolar
Learn More
- Standard Monopolar Footswitch
- Water Resistant Design
- Non-Skid Rubber Base
- Compatible With All Force Series ESU Generators
- Dimensions: 10in x 12in x 6in
- Weight: 6.5lbs
- Cord Length: 10ft
*** SOLD WITH SYSTEM ONLY *** -
Used
-
UsedCONMED 60-5104-001 MONOPOLAR FOOTSWITCH
Learn More -
Used
Conmed 60-6700-001 Monopolar Footswitch
Learn More
- Low Profile, waterproof, 15ft cable
- For use with System 5000, System 2450, Sabre 180, and System 7550 ABC ESUs -
Used
Conmed 60-5103-001 Bipolar Footswitch
Learn More
- Splashproof -
Used
-
Used
Valleylab E-8007 ESU Cart
Learn More
13 x 21 inch top
(price includes new paint) -
Used
ValleyLab E-8006 ESU Cart With Shelf, 16in x 25in Top
Learn More -
New
-
Used
-
UsedSTRYKER SERFAS RADIO FREQUENCY
SYSTEM, RF GENERATOR W/A BUILT-IN
MICROPROCESSOR AND TROUBLESHOOT-
ING GUIDE, PROVIDES VOICE FEEDBACK
WITH DESIRED LANGUAGE SETTINGS TO HELP
THE SURGEON EASILY ADJUST AND IDENTIFY
POWER SETTINGS. CONSOLES AVAILABLE FOR
STANDARD 115V AC OR 220V POWER OUTLETS
Learn More -
Used
Somnoplasty’s Radio Frequency (RF) Energy İs A Minimally İnvasive Surgical Technology That Uses A Controlled Radiofrequency Current To Reduce Tissue Volume İn A Precise And Controlled Manner.
Learn More
This Technique Creates Lesions With Minimal İmpact On Surrounding Tissues, Making İt Appropriate For Delicate Areas. The Necrotic Tissue İn The Lesions İs Gradually Reabsorbedas Part Of The Body’s Natural Process, Thus Reducing Tissue Volume.
Somnoplasty’s RF Energy Uses A Low Power Level And A Low Voltage To Generate Low Tissue Temperatures, İn Order To Create The Largest Predictable Lesions That Produce The Most Effective Controlled Outcomes.
Somnoplasty®
Somnoplasty handpıeces delıver predıctable lesıons up to 14x larger than competıng rf technologıes
Somnoplasty’s Radio Frequency (RF) Energy İs A Minimally İnvasive Surgical Technology That Uses A Controlled Radiofrequency Current To Reduce Tissue Volume İn A Precise And Controlled Manner. This Technique Creates Lesions With Minimal İmpact On Surrounding Tissues, Making İt Appropriate For Delicate Areas. The Necrotic Tissue İn The Lesions İs Gradually Reabsorbedas Part Of The Body’s Natural Process, Thus Reducing Tissue Volume. Somnoplasty’s RF Energy Uses A Low Power Level And A Low Voltage To Generate Low Tissue Temperatures, İn Order To Create The Largest Predictable Lesions That Produce The Most Effective Controlled Outcomes.
Plasmacision®
Plasmaknıfe™ tıps delıver narrower thermal margınes, up to 2x smaller than competıng technologıes
Plug İnto A New World Of Surgical Options With The Universal Plasmacision® (UPC) Reuable Handpiece And İts Eco-Friendly Line Of Disposable Tips. Plasmacision İs An Expression Of PK Technology. It İs An Advanced RF Surgical Technology That Cuts And Cougulates Precisely, Cleanly, Hemostatically And Safely. Using A Proprietary Bipolar RF Output And A Unique Plasmaknife İnstrument Design, Plasmacision Gently Divides Tissue With Selectable Thermal Magrin Control, Providing The Conditions Needed For Less Pain And Quicker Healing.
Convenıent. Intuıtıve. Eco – Frıendly.
“Plug & Play” Set-Up
No Additional Equipment Required (E.G. Saline Or Grounding Pads)
Straight-Throught Suction
180° Rotation: 90° Left And Right From Center Position (With Audible Clicks)
Malleable (TA2 Disposable Plasmaknife Tip Only)
30% Less Post-Consumer Packaging Waste*