Arthroscopy
ARTHROSCOPY
ARTHROSCOPES
Arthroscopes are quite complex in nature, being a sealed, water-tight device consisting of glass rod lenses in a fiber optic tube. As arthroscopes have evolved over the years, the fiber optic and glass rod technologies have improved greatly, allowing for improved clarity, wider field of view, increased magnification, and improved light transmission.
The clarity of the optics is dependent on the internal condition of the scope. Over time, particulate can build up inside a sealed scope, causing a cloudy image that requires disassembly and cleaning to remedy. Additionally, the glass rod lenses can be easily damaged, chipped, or broken, and this will also affect the quality of the image. Then there is the distal objective lens; this can be easily scratched by shavers and burrs during procedures. In some cases, these scratches can be removed by polishing, but it is important to not change the angle or degree of view by over-polishing. The fiber optic light bundle within the scope is another important component and can deteriorate over time, or be damaged by autoclaving a non-autoclavable scope or overheating an autoclavable scope. Damage to the light bundle will cause poor light transmission.
We take all of this into account when inspecting our arthroscopes in order to only offer items that meet the highest quality standards. All of our used arthroscopes are up to manufacturers' specifications, so be aware when buying from non-professional equipment suppliers who do not pay attention to these details.
Arthroscopes are available in autoclavable and non-autoclavable versions of the same scope. Most newer arthroscopes are autoclavable, designed to withstand the extreme heat of sterilization, while the non-autoclavable version will be damaged in these conditions.
Warning : If not performed properly, sterilizing a scope using a manually operated table-top autoclave can be quite damaging to the scope.
STANDARD EYEPIECE ARTHROSCOPES – Attaches to any standard video camera coupler.
SCREW ON C-MOUNT EYEPIECE ARTHROSCOPES - Prevents fogging
The concept of an eyepiece that screws on to the camera head is it provides a waterproof seal between the camera head lens and the scope lens to prevent fogging. They are available in C-Mount style, one inch/25mm.
CARTRIDGE EYEPIECE ARTHROSCOPES - Prevents fogging
Proprietary design specific to the manufacturer and requires a specific camera head.
We offer complete repair and rebuilding of all major brands of arthroscopes. Repairs generally range from $200.00 to $800.00 and up.
ARTHROSCOPY CANNULAS
Arthroscopes require arthroscopy cannulas, and these are specific by brand and size. We try to maintain cannula inventories for the telescopes we offer, and these come in multi-part sets. Single and dual stopcock systems are available in fixed or rotating versions. Inserts come with the cannula, in blunt, conical, or trocar point.
ARTHROSCOPY INSTRUMENTS
We carry a full line of brand new, MADE IN THE USA, premium arthroscopy hand instruments in 2.75mm for small joint procedures, and 3.4mm for large joint prodecures. We also offer used and refurbished arthroscopic hand instruments, knives, probes, rasps, egress cannulas, and shaver blade cannula sets.
We focus heavily in arthroscopy, so let us help you customize the instrument set that best meets your specific needs.
Additionally, under our table accessories category, we often have arthroscopic leg holders and shoulder positioners for your consideration.
ARTHROSCOPY SHAVERS
We offer a variety of brand-name small and large joint arthroscopy shaver systems by manufacturers such as Stryker, Smith & Nephew Dyonics and Linvatec Conmed (which is the same as Concept). A key consideration when purchasing a used shaver system is the availability of the disposable shaver burrs and blades. These are specific to the various manufacturers.
ARTHROSCOPY SHAVER BLADES AND BURRS
We carry systems that can be supported by our complete line of brand new, after-market burrs and blades for Stryker, Dyonics, and Conmed Linvatec. Brand name liquidation shaver blades are available through us as well as on the open market.
ARTHROSCOPY IRRIGATION
We carry arthroscopic irrigation pumps. However, these systems require disposables that we only carry as they become available to us in the liquidation market. Otherwise they have to be sourced from the manufacturer or on the open market.
RADIOFREQUENCY GENERATORS
We also carry radiofrequency and other thermal ablation devices such as Dyonics Vulcan, Stryker Serfas, and Arthrocare Coblator. However, these require disposables that must be sourced from the manufacturer or on the open market.
ARTHROSCOPY IMPLANTS
ACL and shoulder implants can be found under our Sports Medicine section.
-
UsedSTRYKER 275-601-800 6K MICRO SHAVER
HANDPIECE
- REQUIRES FOOTSWITCH
- FOR USE WITH TPS CONSOLE
Learn More -
UsedSTRYKER TOTAL PERFORMANCE SYSTEM
RUNS TPS HAND PIECES
120V 50/60 Hz
STRYKER FORMULA / CORE SHAVER HANDPIECE
MODEL: 375-701-500
STRYKER TPS FOOTSWITCH
(FOOTSWITCH MODEL MAY VARY)
Learn More -
UsedSTRYKER TOTAL PERFORMANCE SYSTEM
RUNS TPS HAND PIECES
120V 50/60 Hz
STRYKER FORMULA / CORE SHAVER HANDPIECE
WITH HAND BUTTON CONTROLS
MODEL: ENAS-S-375-704
Learn More -
UsedSTRYKER 375-708-500 FORMULA 180 SHAVER
HANDPIECE WITH BUTTONS
- UP TO 12,000 RPMS
- 12ft CABLE
- SHAVER BLADE RECOGNITION
- FOR USE WITH CORE AND/OR TPS CONSOLES
Learn More -
UsedSTRYKER 5400-50 CORE CONSOLE ONLY
REF 5400-050-000
RUNS ALL 5400 CORE SERIES
HANDPIECES
OPERATES TWO HANDPIECES SIMULTANEOUSLY
INTEGRATED IRRIGATION PUMP
ENHANCED FLOW-RATE CONTROL
INTUITIVE COLOR TOUCH SCREEN DISPLAY
FULLY CUSTOMIZABLE USER PREFERENCES
Learn More -
Used
STRYKER CORE SHAVER SYSTEM
RUNS ALL 5400 CORE SERIES HANDPIECES
Learn More
SYSTEM CONSISTS OF:
- CONSOLE
- HANDPIECE -
Used
Arthrex AR-8310 Low Profile Footswitch
For Use With APS II Control Console*** Sold With System Only ***
Learn More -
Used
-
UsedLINVATEC D9824 ADVANTAGE SHAVER
HANDPIECE
- TWO-BUTTON
- FORWARD/REVERSE: 500 - 10,000 RPM
- OSCILLATE: 500 - 2,500 RPM
- TORQUE: 22 in oz
- LENGTH: 6.1 in
- WEIGHT: 15.8 oz (450g)
- CORD LENGTH: 10 ft (3m) NON-DETACHABLE
- FOR USE WITH LARGE HUB SHAVER BLADES &
BURS
- FOR USE WITH ADVANTAGE, E9000 AND
POWERPRO CONSOLES
Learn More -
UsedLINVATEC C9840 APEX SMALL JOINT HANDPIECE
WITH CORD
- REQUIRES FOOTSWITCH
- WORKS WITH: APEX ADVANTAGE
Learn More -
UsedLINVATEC MC9840 MICROCHOICE MICRO SHAVER
HANDPIECE
- FORWARD SPEED: 300 - 6,000 RPM
- OSCILLATE SPEED: 300 - 2,500 CPM
- SINGLE AND MULTI-TURN OSCILLATE
- WEIGHT: 8.4 oz (237g)
- FOR USE WITH MICRO HUB SMALL JOINT
BLADES AND BURS
- FOR USE WITH ADVANTAGE, E9000 AMD
POWERPRO CONSOLES
Learn More -
Used
LINVATEC ADVANTAGE SHAVER SYSTEM
Learn More
OFFERED WITO ONE HANDPIECE
SMALL JOINT OR STANDARD
FOOT CONTROL REQUIRED WITH NON
FINGER ACTION BUTTON HAND PIECES -
Used
-
Used
ARTHREX APS II CONTROL CONSOLE - ONLY
Learn More
MODEL: AR-8300
- POWER REQUIREMENTS: 110 - 240 VAC, 6.3 A
50/60 Hz, T 6.3 Amp
- POWER CONSUMPTION: 10 A / 250 V
- DIMENSIONS: 14.5in W x 5.2in H x 12.8in D
- WEIGHT: 16.6 lbs. -
UsedARTHREX CONTINUOUS WAVE III CONTROL UNIT
ARTHROSCOPY PUMP - ONLY -
MODEL: AR-6475
- MAXIMUM FLOW: 1500mL/MINUTE MINIMUM
- PRESSURE: 0 - 120mmHg
- DIMENSIONS: 14.5in W x 5in H x 12in D
- WEIGHT: 18 lbs.
Learn More -
Used
Arthrex Synergy Resection Console ar-8305:
Learn More
This versatile system has a touch-panel control with an intuitive graphic user interface and was designed for multiple orthopedic procedures. The SynergyResection shaver features 2 fully functional channels that allow optional simultaneous handpiece operation. Use a single footswitch to control both channels, or attach a second footswitch to the console to operate each channel individually. The SynergyResection shaver has a maximum speed of 8000 revolutions per minute, providing precise burr control during surgical procedures.
The SynergyResection shaver’s setting can be displayed on the operative monitor when connected to the SynergyHD3™ console (rev x.6 or higher) using a dedicated cable (available as an optional add-on to the SynergyHD3 console). -
Used
Forward Speed 500-12,000rpm
Oscillate Speed 500-2,500cpm, Single and Multi Turn Oscillate
Learn More -
Used
Rack For Arthroscopic Instruments
Learn More
- Holds up to 10 instruments
- 11in W x 9.5in D x 4.75in High
- Fits the small Genesis style cases (Measuring 11in x 12in x 5in) -
UsedDEPUY MITEK 214004 EXPRESSEW II FLEXIBLE
SUTURE PASSER, USED
- JAW RATCHET/RATCHET RELEASE
- NEEDLE AUTO RETRACTION
- SIMPLIFIED NEEDLE AND SUTURE LOADING
- FLEXIBLE FOR MEDIAL AND LATERAL ROWS
- CLAM SHELL JAW DESIGN PROVIDES >16mm
TISSUE BITE
- 4.5mm PROFILE
- WORKS WITH 214005 EXPRESSEW NEEDLES
Learn More -