Arthroscopy
ARTHROSCOPY
ARTHROSCOPES
Arthroscopes are quite complex in nature, being a sealed, water-tight device consisting of glass rod lenses in a fiber optic tube. As arthroscopes have evolved over the years, the fiber optic and glass rod technologies have improved greatly, allowing for improved clarity, wider field of view, increased magnification, and improved light transmission.
The clarity of the optics is dependent on the internal condition of the scope. Over time, particulate can build up inside a sealed scope, causing a cloudy image that requires disassembly and cleaning to remedy. Additionally, the glass rod lenses can be easily damaged, chipped, or broken, and this will also affect the quality of the image. Then there is the distal objective lens; this can be easily scratched by shavers and burrs during procedures. In some cases, these scratches can be removed by polishing, but it is important to not change the angle or degree of view by over-polishing. The fiber optic light bundle within the scope is another important component and can deteriorate over time, or be damaged by autoclaving a non-autoclavable scope or overheating an autoclavable scope. Damage to the light bundle will cause poor light transmission.
We take all of this into account when inspecting our arthroscopes in order to only offer items that meet the highest quality standards. All of our used arthroscopes are up to manufacturers' specifications, so be aware when buying from non-professional equipment suppliers who do not pay attention to these details.
Arthroscopes are available in autoclavable and non-autoclavable versions of the same scope. Most newer arthroscopes are autoclavable, designed to withstand the extreme heat of sterilization, while the non-autoclavable version will be damaged in these conditions.
Warning : If not performed properly, sterilizing a scope using a manually operated table-top autoclave can be quite damaging to the scope.
STANDARD EYEPIECE ARTHROSCOPES – Attaches to any standard video camera coupler.
SCREW ON C-MOUNT EYEPIECE ARTHROSCOPES - Prevents fogging
The concept of an eyepiece that screws on to the camera head is it provides a waterproof seal between the camera head lens and the scope lens to prevent fogging. They are available in C-Mount style, one inch/25mm.
CARTRIDGE EYEPIECE ARTHROSCOPES - Prevents fogging
Proprietary design specific to the manufacturer and requires a specific camera head.
We offer complete repair and rebuilding of all major brands of arthroscopes. Repairs generally range from $200.00 to $800.00 and up.
ARTHROSCOPY CANNULAS
Arthroscopes require arthroscopy cannulas, and these are specific by brand and size. We try to maintain cannula inventories for the telescopes we offer, and these come in multi-part sets. Single and dual stopcock systems are available in fixed or rotating versions. Inserts come with the cannula, in blunt, conical, or trocar point.
ARTHROSCOPY INSTRUMENTS
We carry a full line of brand new, MADE IN THE USA, premium arthroscopy hand instruments in 2.75mm for small joint procedures, and 3.4mm for large joint prodecures. We also offer used and refurbished arthroscopic hand instruments, knives, probes, rasps, egress cannulas, and shaver blade cannula sets.
We focus heavily in arthroscopy, so let us help you customize the instrument set that best meets your specific needs.
Additionally, under our table accessories category, we often have arthroscopic leg holders and shoulder positioners for your consideration.
ARTHROSCOPY SHAVERS
We offer a variety of brand-name small and large joint arthroscopy shaver systems by manufacturers such as Stryker, Smith & Nephew Dyonics and Linvatec Conmed (which is the same as Concept). A key consideration when purchasing a used shaver system is the availability of the disposable shaver burrs and blades. These are specific to the various manufacturers.
ARTHROSCOPY SHAVER BLADES AND BURRS
We carry systems that can be supported by our complete line of brand new, after-market burrs and blades for Stryker, Dyonics, and Conmed Linvatec. Brand name liquidation shaver blades are available through us as well as on the open market.
ARTHROSCOPY IRRIGATION
We carry arthroscopic irrigation pumps. However, these systems require disposables that we only carry as they become available to us in the liquidation market. Otherwise they have to be sourced from the manufacturer or on the open market.
RADIOFREQUENCY GENERATORS
We also carry radiofrequency and other thermal ablation devices such as Dyonics Vulcan, Stryker Serfas, and Arthrocare Coblator. However, these require disposables that must be sourced from the manufacturer or on the open market.
ARTHROSCOPY IMPLANTS
ACL and shoulder implants can be found under our Sports Medicine section.
-
UsedSTORZ 30' 2.7MM AUTOCLAVEABLE ARTHROSCOPE Learn More
-
Used
1 Conmed Linvatec D3000 Advantage Shaver Console
- Operates Advantage, Apex, PowerPro Electric, Microchoice, Mini-Driver, and E9000 Handpieces
- Overall Dimensions: 5.13in H x 17in W x 13in D
- Weight: 19.5lbs1 Single Trigger Handpiece -Pro6100
1 Pin Driver- Pro6032
- CANNULATED: .78in - .125in (2mm - 3.2mm)1 Wire Driver -Pro6028
Learn More
- CANNULATED: .028in - .062in (.7mm - 1.6mm)
1 1/4" Jacobs Chuck- Pro2041
1 Trinkle -Pro2029
1 Adaptor/Cable -
Used
WOLF 70' 4MM PANOVIEW TELESCOPE
Learn More
ADD CANNULA SET FOR $250.00 -
Used
-
Used
LINVATEC HD4301 4mm, 30° ARTHROSCOPE,
AUTOCLAVABLE, EYEPIECE TYPEFOR USE WITH:
QL5531 - 5.5MM ARTHROSCOPY SHEATH SET, SINGLE
QL5532 - 5.5MM ARTHROSCOPY SHEATH SET, DUAL
QL6131 - 5.9MM HIGH FLOW SHEATH SET, SINGLE
QL6132 - 5.9MM HIGH FLOW SHEATH SET, DUAL
QL6231 - 5.9MM TWO-CONNECT SHEATH SET, SINGLE
QL6232 - 5.9MM TWO-CONNECT SHEATH SET, DUAL
QLR6131 - 5.9MM HIGH FLOW SHEATH SET REV, SINGLE
QLR6132 - 5.9MM HIGH FLOW SHEATH SET REV, DUALQL6111 - QUICKLATCH BRIDGE SYSTEM, SINGLE STOPCOCK
Learn More
QL6112 - QUICKLATCH BRIDGE SYSTEM, DUAL STOPCOCK
QL6210 - TWO-CONNECT, WITH QL6230, T5101 OR T5102 -
UsedConcept Linvatec 4mm 90° Arthroscope Learn More
-
New
WHITTEMORE 1 MM X 0º X 120MM NEEDLE
Learn More
TELESCOPE
SET INCLUDES:
DIAGNOSTIC SHEATH WITH
STOPCOCKS, 2.2MM x 4mm OUTSIDE DIAMETER
AND 2.00 MM INSIDE DIAMETER
FOR ARTHROSCOPY, BIRD SEXING, REPTILES,
AND EXOTICS -
NewWHITTEMORE 2.7MM X 30º X 175MM TELESCOPE
USE WITH ARTHROSCOPY AND OPERATING SHEATHS
(WE-175MM-SHEATH-DUAL, WE-175MM-SHEATH-SINGLE,
AND WE-175MM-SHEATH-OPERATING)
FOR OTOSCOPY, ARTHROSCOPY, RHINOSCOPY
Learn More -
New
WHITTEMORE 2.7MM X 30º X 108MM TELESCOPE
Learn More
USE WITH ARTHROSCOPY SHEATH (WE-105MM-ARTHRO-S),
OPERATING SHEATH (WE-105MM-OPERATING,
OTOSCOPE SHEATH (WE-105MM-OTO-SHEATH)
FOR OTOSCOPY, ARTHROSCOPY, RHINOSCOPY -
NewWHITTEMORE 2.7MM X 0º X 105MM TELESCOPE
USE WITH ARTHROSCOPY SHEATH (WE-105MM-ARTHRO-S),
OPERATING SHEATH (WE-105MM-OPERATING),
OTOSCOPE SHEATH (WE-105MM-OTO-SHEATH)
FOR OTOSCOPY, ARTHROSCOPY, RHINOSCOPY
Learn More -
Used
-
Used
Stryker 502-704-030 4.0mm 30° Ideal Eyes Video Arthroscope
Learn More
Features/Specifications:
- Ideal Eyes, HD, Autoclavable C-Mount Arthroscope
- Improved center to edge resolution
- Resolution and brightness are enhanced across the entire field of view for optimal image quality
- Enhanced outer radius line per millimeter enhanced from 11.4 horizontal lines on currect scopes to 12.8 horizontal lines on Ideal Eyes scopes
- New magnetic drive focus ring design
- Optimal moisture resistance
- Improved reliability during all sterlization methods
- Precise focusing of the scope with one hand
- Outer Diameter: 4.0mm
- View Direction: 30°
- Field Of View: 105°
- Working Length: 140mm
- Light Post Direction: Standard
- Locking Mechanism: Speed-Lock -
Used
Stryker 502-704-070 4.0mm 70° Ideal Eyes Video Arthroscope
Learn More
Features/Specifications:
- Ideal Eyes, HD, Autoclavable C-Mount Arthroscope
- Improved center to edge resolution
- Resolution and brightness are enhanced across the entire field of view for optimal image quality
- Enhanced outer radius line per millimeter enhanced from 11.4 horizontal lines on currect scopes to 12.8 horizontal lines on Ideal Eyes scopes
- New magnetic drive focus ring design
- Optimal moisture resistance
- Improved reliability during all sterlization methods
- Precise focusing of the scope with one hand
- Outer Diameter: 4.0mm
- View Direction: 70°
- Field Of View: 105°
- Working Length: 140mm
- Light Post Direction: Standard
- Locking Mechanism: Speed-Lock -
Used
-
Used
-
Used
-
Used
-
Used
-
Used
Linvatec 7584 4mm 70° Wide Angle Arthroscope
Learn More -
Used
Linvatec T2930 2.9mm 30° Quicklatch Arthroscope
- Autoclavable
- Field Of View: 105°
- Working Length: 151.7mm
- Allows for greater access and maneuverability while maintaining a field of view equivalent to that of a 4mm scope
- Smaller aperture imrpoves depth of field without compromising image sizeFor use with the following sheaths and bridges:
T4031 - 4.0mm small joint, single
T4731 - 4.7mm arthroscopy, single
T4931 - 5.2mm high flow, single
T5131 - 5.2mm Two-Connect, singleT4032 - 4.0mm small joint, dual
Learn More
T4732 - 4.7mm arthroscopy, dual
T4932 - 5.2mm high flow, dual
T5132 - 5.2mm Two-Connect, dual
T4911 - single stopcock bridge
T4912 - dual stopcock bridge
T4910 - Two-Connect (with T5130, T5101 or T5102) -
Used
LINVATEC T2571 2.5mm, 70° SMALL JOINT ARTHROSCOPE,
Learn More
AUTOCLAVABLE, CARTRIDGE TYPE
FOR USE WITH:
C3252 - 3.5MM SHEATH SET, DUAL
C3252-30 - 3.5MM SHEATH SET WITH 30 DEGREE TIP, DUAL -
Used
-
UsedSmith & Nephew Dyonics 3626 4.0mm 30° Video Arthroscope
Features:
- For Arthroscopy and examination/treatment of nasal cavities and nasal pharynx
- Non-Autoclavable; Stainless steel construction to withstand chemical sterlization modalities (EtO, Steris, and Sterrad)
- Wide angle of view and ergonomically designed to directly attach to the camera head for ease of use
- Insertion needle is fully rotatable without the need to reposition the camera head
- For use only with the Smith & Nephew ED3, 360, 460, HD900 and 111 camera heads; Not compatible with the 470 or 560 camera heads
Specifications:
- Focus Ring: Blue
- Focal Length: 35mm
- Outer Diameter: 4.0mm
- Direction Of View: 30°
- Field Of View: 115°
- Working Length: 160mm
- Light Post Direction: Opposite
- Cannula Connection: J-Lock
- Recommended Light Cable: 5.0mm
Learn More -
Used
Smith & Nephew Dyonics 3797 2.7mm 70° Video Arthroscope
VideoArthroscopes, Non-Autoclavable
Indications: Arthroscopy and examination/treatment of nasal cavities and nasal pharynx
• Stainless steel construction to withstand chemical sterilization modalities (EtO and Sterrad TM)
• Wide angle of view
• Ergonomically designed to directly attach to the camera head for ease of use and reduce
number of interface where fogging could occur
• Insertion needle is fully rotatable without the need to reposition the camera head
• Compatible with Smith &
Nephew Non-Autoclavable
Camera Heads (C-Mount), as listed belowThese VideoArthroscopes for use only with the Smith & Nephew ED3, 360, 460 and HD900 camera heads.
Not compatible with the Smith & Nephew 470 or 560 camera heads
Learn More
Specifications:
- Focus Ring: Blue
- Outer Diameter: 2.7mm
- Direction Of View: 70°
- Field Of View: 90°
- Working Length: 70mm
- Light Post Direction: Opposite
- Cannula Connection: J-Lock
- Recommended Light Cable: 4.0mm -
Used
Smith & Nephew Dyonics 3768 2.7mm 30° Video Arthroscope
Learn More
Features:
- For Arthroscopy and examination/treatment of nasal cavities and nasal pharynx
- Non-Autoclavable; Stainless steel construction to withstand chemical sterlization modalities (EtO, Steris, and Sterrad)
- Wide angle of view and ergonomically designed to directly attach to the camera head for ease of use
- Insertion needle is fully rotatable without the need to reposition the camera head
- For use only with the Smith & Nephew ED3, 360, 460, HD900 and 111 camera heads; Not compatible with the 470 or 560 camera heads
Specifications:
- Focus Ring: Blue
- Focal Length: 35mm
- Outer Diameter: 2.7mm
- Direction Of View: 30°
- Field Of View: 90°
- Working Length: 67mm
- Light Post Direction: Opposite
- Cannula Connection: J-Lock
- Recommended Light Cable: 4.0mm -
UsedDYONICS 4.0mm 30° VIDEO ARTHROSCOPE,
AUTOCLAVABLE
- WORKS WITH 337, 350, & 370 CAMERA HEADS,
V-MOUNT
- WORKING LENGTH: 160mm
Learn More -
UsedDYONICS 4MM 30' VIDEO ARTHROSCOPE
35MM FOCAL LENGTH, 160MM WORKING LENGTH
NON-AUTOCLAVEABLE
Learn More -
Used
-
Used
-
Used
-
Used
-
Used
-
Used
-
Used
-
Used
STORZ 2.8 MM ARTHROSCOPY SHEATH
Learn More
WITH 1 STOPCOCK
106 mm Long
USE WITH 28301B 1.9 mm SCOPE -
Used
-
Used
-
Used
-
Used
-
Used
-
Used
-
NewWHITEMORE OPERATING SHEATH,
WITH OBTURATOR, DUAL STOPCOCK,
2MM CHANNEL
FOR USE WITH 2.7MM X 175 MM SCOPE
(WE-175MM-2.7-0-A OR WE-175MM-2.7-30-A)
FOR RHINOSCOPY, CYSTOSCOPY
Learn More -
New
-
Used
-
Used
-
UsedAcufex 012043 Scoop Basket Punch, 1.3mm Upbiter, Curved Right - Traditional style, classical punch shape with the parrot beak upper jaw to help capture tissue - Tip Profile: 2.10mm - Bite Width: 1.59mm - Tip Width: 3.27mm Learn More
-
UsedAcufex 012034 Scoop Basket Punch, 1.5mm Straight - Traditional style, classical punch shape with the parrot beak upper jaw to help capture tissue - Tip Profile: 2.28mm - Bite Width: 1.59mm - Tip Width: 3.88mm Learn More
-
UsedSTRYKER CONQUEST 300034203 NARROW PUNCH,15' UP, 3.4MM Learn More
-
UsedSTRYKER CONQUEST 300034600 HOOK SCISSORS, STRAIGHT, 3.4MM Learn More
-
UsedSTRYKER CONQUEST 300034300 SCOOP JAW PUNCH, STRAIGHT, 3.4MM Learn More
-
UsedSTRYKER CONQUEST 300034951 SOFT TISSUE GRASPER, 3.4MM Learn More
-
Used
Mitek / Surgical Solutions EXPRESSEW
Learn More
Flexible Suture Passer w/ Reusable Handle -
UsedSTRYKER CONQUEST 300034701 GRASPER, 3.4MM Learn More
-
UsedSTRYKER CONQUEST 300034104 BIG BITE PUNCH, UPSHAFT, 3.4MM Learn More
-
UsedSTRYKER CONQUEST 300024100 BIG BITE PUNCH, STRAIGHT, 3.4MM Learn More
-
UsedSTRYKER CONQUEST 300027100 BIG BITE PUNCH, STRAIGHT, 2.7MM Learn More
-
UsedARTHREX 3.4MM PUNCH ROTARY 90' LEFT TIP, STRAIGHT SHAFT, WIDEBITER Learn More
-
UsedAcufex 010813 Rotary Scissor, 20° Hooked Right Learn More
-
UsedARTHREX 3.4MM PUNCH ROTARY 90' RIGHT TIP, STRAIGHT SHAFT, WIDEBITER Learn More
-
Used
ARTHROSCOPIC INSTRUMENTS USED
Learn More
Various Brands Karl Storz, Concept, Shutt, Dyonics. -
Used
-
Used
-
UsedAcufex 013600 PCL Drill Guide System Set
Includes:
1 - PCL Handle (013630)
1 - Femoral Pin Guide
1 - Femoral Aimer (013539)
1 - Tibial Aimer (013602)
1 - 2.4mm Dril Sleeve (013646)
1 - Screwdriver (013629)
1 - Drill Stop, 6mm (013620)
1 - Drill Stop, 7mm (013621)
1 - Drill Stop, 8mm (013622)
1 - Drill Stop, 9mm (013623)
1 - Drill Stop, 10mm (013624)
1 - Drill Stop, 11mm (013625)
1 - Drill Stop, 12mm (013626)
1 - Closed Femoral Curette (013674)
1 - Open Tibial Curette (013673)
1 - Tibial Hook Knife (013672)
1 - Closed Tibial Curette (013671)
1 - Tibial Rasp (013670)
1 - Sterilization Case
Learn More -
UsedAcufex 013382 Shoulder Accessory Kit
Includes:
1 - Tissue Tensioner Grasper, Cannulated (014779)
1 - Shoulder Stitcher, 45° (013947)
1 - Knife Rasp (013977)
1 - Shoulder Rod, 4mm (013948)
1 - Shoulder Rod Guide, 7mm (013950)
1 - Glenoid Guide (013447)
1 - Sterilization Case (011633)
Learn More -
Used
-
UsedARTHREX AR-13900 VIPER SUTURE PASSER Learn More
-
Used
-
Used
-
Used
-
UsedAcufex 012051 Narrowline Basket Punch, Upbiter
- Narrow shaft and compact jaw design facilitates access and use in tight spaces, particularly useful in the posterior aspect of the knee
- Tip Profile: 1.9mm
- Bite Width: 1.67mm
- Tip Width: 2.89mm
Learn More -
UsedAcufex 012045 DUCKLING Basket Punch, Upbiter
- Lower profile in relation to the DUCKBILL, maintaining a large square bite and maximizing maneuverability
- Tip Profile: 1.93mm
- Bite Width: 3.17mm
- Tip Width: 5mm
Learn More -
UsedAcufex 012042 Scoop Basket Punch, 1.3mm Upbiter, Curved Left
- Traditional style, classical punch shape with the parrot beak upper jaw to help capture tissue
- Tip Profile: 2.10mm
- Bite Width: 1.59mm
- Tip Width: 3.27mm
Learn More -
Used
Acufex 7207200 Oval Punch, Upbiter
Learn More
- Lowest profile and the largest bite, facilitating end-on and lateral cutting
- Tip Profile: 1.65mm
- Bite Width: 4.39mm
- Tip Width: 6.57mm -
Used
-
Used
-
Used
-
Used
-
Used
-
Used
-
Used
-
Used
-
Used
-
Used
-
Used
-
UsedACUFEX 012037 SCISSOR PUNCH, UPBITER
Learn More -
Used
-
Used
-
Used
-
Used
-
Used
-
Used
Linvatec Shutt 18.1009 4mm Suture Punch, Curved Right
Learn More -
Used
Linvatec Shutt 18.10011 4mm Suture Punch, Curved Left
Learn More -
Used
Linvatec Shutt 18.1008 4mm Suture Punch, Straight, Slotted Jaw
Learn More -
Used
Linvatec Shutt 18.1007 4mm Suture Punch, Straight
Learn More -
Used
-
Used
-
Used
-
Used
-
UsedDEPUY MITEK 214004 EXPRESSEW II FLEXIBLE
SUTURE PASSER, USED
- JAW RATCHET/RATCHET RELEASE
- NEEDLE AUTO RETRACTION
- SIMPLIFIED NEEDLE AND SUTURE LOADING
- FLEXIBLE FOR MEDIAL AND LATERAL ROWS
- CLAM SHELL JAW DESIGN PROVIDES >16mm
TISSUE BITE
- 4.5mm PROFILE
- WORKS WITH 214005 EXPRESSEW NEEDLES
Learn More -
Used
Rack For Arthroscopic Instruments
Learn More
- Holds up to 10 instruments
- 11in W x 9.5in D x 4.75in High
- Fits the small Genesis style cases (Measuring 11in x 12in x 5in)