Arthroscopy
ARTHROSCOPY
ARTHROSCOPES
Arthroscopes are quite complex in nature, being a sealed, water-tight device consisting of glass rod lenses in a fiber optic tube. As arthroscopes have evolved over the years, the fiber optic and glass rod technologies have improved greatly, allowing for improved clarity, wider field of view, increased magnification, and improved light transmission.
The clarity of the optics is dependent on the internal condition of the scope. Over time, particulate can build up inside a sealed scope, causing a cloudy image that requires disassembly and cleaning to remedy. Additionally, the glass rod lenses can be easily damaged, chipped, or broken, and this will also affect the quality of the image. Then there is the distal objective lens; this can be easily scratched by shavers and burrs during procedures. In some cases, these scratches can be removed by polishing, but it is important to not change the angle or degree of view by over-polishing. The fiber optic light bundle within the scope is another important component and can deteriorate over time, or be damaged by autoclaving a non-autoclavable scope or overheating an autoclavable scope. Damage to the light bundle will cause poor light transmission.
We take all of this into account when inspecting our arthroscopes in order to only offer items that meet the highest quality standards. All of our used arthroscopes are up to manufacturers' specifications, so be aware when buying from non-professional equipment suppliers who do not pay attention to these details.
Arthroscopes are available in autoclavable and non-autoclavable versions of the same scope. Most newer arthroscopes are autoclavable, designed to withstand the extreme heat of sterilization, while the non-autoclavable version will be damaged in these conditions.
Warning : If not performed properly, sterilizing a scope using a manually operated table-top autoclave can be quite damaging to the scope.
STANDARD EYEPIECE ARTHROSCOPES – Attaches to any standard video camera coupler.
SCREW ON C-MOUNT EYEPIECE ARTHROSCOPES - Prevents fogging
The concept of an eyepiece that screws on to the camera head is it provides a waterproof seal between the camera head lens and the scope lens to prevent fogging. They are available in C-Mount style, one inch/25mm.
CARTRIDGE EYEPIECE ARTHROSCOPES - Prevents fogging
Proprietary design specific to the manufacturer and requires a specific camera head.
We offer complete repair and rebuilding of all major brands of arthroscopes. Repairs generally range from $200.00 to $800.00 and up.
ARTHROSCOPY CANNULAS
Arthroscopes require arthroscopy cannulas, and these are specific by brand and size. We try to maintain cannula inventories for the telescopes we offer, and these come in multi-part sets. Single and dual stopcock systems are available in fixed or rotating versions. Inserts come with the cannula, in blunt, conical, or trocar point.
ARTHROSCOPY INSTRUMENTS
We carry a full line of brand new, MADE IN THE USA, premium arthroscopy hand instruments in 2.75mm for small joint procedures, and 3.4mm for large joint prodecures. We also offer used and refurbished arthroscopic hand instruments, knives, probes, rasps, egress cannulas, and shaver blade cannula sets.
We focus heavily in arthroscopy, so let us help you customize the instrument set that best meets your specific needs.
Additionally, under our table accessories category, we often have arthroscopic leg holders and shoulder positioners for your consideration.
ARTHROSCOPY SHAVERS
We offer a variety of brand-name small and large joint arthroscopy shaver systems by manufacturers such as Stryker, Smith & Nephew Dyonics and Linvatec Conmed (which is the same as Concept). A key consideration when purchasing a used shaver system is the availability of the disposable shaver burrs and blades. These are specific to the various manufacturers.
ARTHROSCOPY SHAVER BLADES AND BURRS
We carry systems that can be supported by our complete line of brand new, after-market burrs and blades for Stryker, Dyonics, and Conmed Linvatec. Brand name liquidation shaver blades are available through us as well as on the open market.
ARTHROSCOPY IRRIGATION
We carry arthroscopic irrigation pumps. However, these systems require disposables that we only carry as they become available to us in the liquidation market. Otherwise they have to be sourced from the manufacturer or on the open market.
RADIOFREQUENCY GENERATORS
We also carry radiofrequency and other thermal ablation devices such as Dyonics Vulcan, Stryker Serfas, and Arthrocare Coblator. However, these require disposables that must be sourced from the manufacturer or on the open market.
ARTHROSCOPY IMPLANTS
ACL and shoulder implants can be found under our Sports Medicine section.
-
Used
-
Used
Stryker 502-704-030 4.0mm 30° Ideal Eyes Video Arthroscope
Learn More
Features/Specifications:
- Ideal Eyes, HD, Autoclavable C-Mount Arthroscope
- Improved center to edge resolution
- Resolution and brightness are enhanced across the entire field of view for optimal image quality
- Enhanced outer radius line per millimeter enhanced from 11.4 horizontal lines on currect scopes to 12.8 horizontal lines on Ideal Eyes scopes
- New magnetic drive focus ring design
- Optimal moisture resistance
- Improved reliability during all sterlization methods
- Precise focusing of the scope with one hand
- Outer Diameter: 4.0mm
- View Direction: 30°
- Field Of View: 105°
- Working Length: 140mm
- Light Post Direction: Standard
- Locking Mechanism: Speed-Lock -
Used
Stryker 502-704-070 4.0mm 70° Ideal Eyes Video Arthroscope
Learn More
Features/Specifications:
- Ideal Eyes, HD, Autoclavable C-Mount Arthroscope
- Improved center to edge resolution
- Resolution and brightness are enhanced across the entire field of view for optimal image quality
- Enhanced outer radius line per millimeter enhanced from 11.4 horizontal lines on currect scopes to 12.8 horizontal lines on Ideal Eyes scopes
- New magnetic drive focus ring design
- Optimal moisture resistance
- Improved reliability during all sterlization methods
- Precise focusing of the scope with one hand
- Outer Diameter: 4.0mm
- View Direction: 70°
- Field Of View: 105°
- Working Length: 140mm
- Light Post Direction: Standard
- Locking Mechanism: Speed-Lock -
Used
-
Used
-
Used
-
Used
-
Used
-
Used
-
UsedSTRYKER CONQUEST 300034203 NARROW PUNCH,15' UP, 3.4MM Learn More
-
UsedSTRYKER CONQUEST 300034600 HOOK SCISSORS, STRAIGHT, 3.4MM Learn More
-
UsedSTRYKER CONQUEST 300034300 SCOOP JAW PUNCH, STRAIGHT, 3.4MM Learn More
-
UsedSTRYKER CONQUEST 300034951 SOFT TISSUE GRASPER, 3.4MM Learn More
-
UsedSTRYKER CONQUEST 300034701 GRASPER, 3.4MM Learn More
-
UsedSTRYKER CONQUEST 300034104 BIG BITE PUNCH, UPSHAFT, 3.4MM Learn More
-
UsedSTRYKER CONQUEST 300024100 BIG BITE PUNCH, STRAIGHT, 3.4MM Learn More
-
UsedSTRYKER CONQUEST 300027100 BIG BITE PUNCH, STRAIGHT, 2.7MM Learn More
-
Used
STRYKER CORE SHAVER SYSTEM
RUNS ALL 5400 CORE SERIES HANDPIECES
Learn More
SYSTEM CONSISTS OF:
- CONSOLE
- HANDPIECE -
UsedSTRYKER 5400-50 CORE CONSOLE ONLY
REF 5400-050-000
RUNS ALL 5400 CORE SERIES
HANDPIECES
OPERATES TWO HANDPIECES SIMULTANEOUSLY
INTEGRATED IRRIGATION PUMP
ENHANCED FLOW-RATE CONTROL
INTUITIVE COLOR TOUCH SCREEN DISPLAY
FULLY CUSTOMIZABLE USER PREFERENCES
Learn More -
UsedSTRYKER 375-708-500 FORMULA 180 SHAVER
HANDPIECE WITH BUTTONS
- UP TO 12,000 RPMS
- 12ft CABLE
- SHAVER BLADE RECOGNITION
- FOR USE WITH CORE AND/OR TPS CONSOLES
Learn More