Helping Medical professionals practice state of the art medicine affordably. Since 1983

Vital Signs Monitors

Grid List

Set Descending Direction

9 Item(s)

  1. WE VETERINARY PORTABLE MONITOR FOR SPO2, NIBP, WITH CO2
    New

    3.5" High Resolution Color LCD Screen
    Vital signs parameters: SpO2 + NIBP + CO2
    Provide the parameter of Perfusion Index 0.05%-20%
    Date storage capabilities
    Audio and Visual alarm, Programable alarm upper and lower limit values.
    Lithium ion battery power supply, 8 hrs continuous working, charging dock.

    Includes:

    - Reusable SpO2 Sensor w/ 2 Clips
    - NIBP Veterinary Cuff Pack (Sizes 1-5)
    - NIBP Extension Cable
    - Charging Deck
    - Charging Cable
    - USB Connection

    Learn More
  2. WE VETERINARY MINI MONITOR
    New

    3.5" High Resolution Color LCD Screen
    Vital signs parameters: SpO2 + NIBP + TEMP.
    Provide the parameter of Perfusion Index 0.05%-20%
    Date storage capabilities
    Audio and Visual alarm, Programable alarm upper and lower limit values.
    Lithium ion battery power supply, 8 hrs continuous working, charging dock.

    Includes:

    - Reusable SpO2 Sensor w/ 2 Clips
    - NIBP Veterinary Cuff Pack (Sizes 1-5)
    - NIBP Extension Cable
    - TEMP Probe
    - Charging Deck
    - Charging Cable
    - USB Connection

    ALSO AVAILABLE WITH CO2 Learn More

  3. WE VITAL SIGNS MONITOR
    New

    2.8” Hight brightness TFT LCD display.
    High brightness LED display of NIBP, SpO2 and pulse rate.
    Memory: Built-in Flash Memory.
    Up to 2000 groups NIBP data storage and SpO2 dada up to 48 hours.
    Powerful dada storage and managment, Trend table.
    Visual and Audio alarms, adjustable.
    Audio volume adjustable.
    Built-in rechargeable Li-Polymer.
    Specifications:
    NIBP
    Method: Oscillometry.
    Measurement Range: 25~260mmHg.
    Resolution: 1mmHg.
    NIBP Accuracy: ±5 mmHg.
    Alarm: SYS/DIA/MAP.

    SpO2
    Measurement Range: 0%~100%
    Resolution: 1%
    Accuracy: ±2%(70%~100%),
    0%~69% unspecified.
    Alarm range: 0~100%.

    Pulse Rate
    Measurement Range: 10~270mmHg.
    Resolution: 1bpm.
    Accuracy: ±2bpm or ±2%(select larger)

    Dimension(L×W×H) 191×160 ×244(mm).
    Net weight 191×160×244(mm). 1.5Kg.

    Learn More
  4. picture of Criticare 506NT3 VitalCare Patient Monitor
    Used

     

    Criticare 506NT3 VitalCare Patient Monitor
    With NIBP and FILAC Temp
    ***Does NOT have SpO2***

    Features:
    -  NIBP is oscillometric measure upon inflation and FILAC is predictive of continuous temperature
    -  Adult, Pediatric & Neonatal applications with adjustable audible and visual alarms
    -  Compact design with built-in handle and keypad with large responsive keys
    -  Connectivity to numerous electronic medical record systems

    Specifications:
    NIBP
    -  Pressure Range Adult: 30 - 300mmHg
    -  Pressure Range Pediatric: 30 - 150mmHg
    -  Pressure Range Neonatal: 20 - 150mmHg
    -  Pressure Accuracy: ± 2mmHg
    PULSE
    -  Heart Rate Range: 30 - 300bpm
    -  Heart Rate Accuracy: ±1bpm
    FILAC TEMP
    -  Temp Range: 86° F - 109.4° F
    -  Temp Predictive Accuracy: ±0.2° F
    -  Temp Continuous Accuracy: ±0.2° F
    OTHER:
    -  Trend Memory: 24 Hours
    -  LED Display: SpO2, Pulse, NIBP, Temp & Pulse Bar
    -  Battery Life: 8 Hours Typical
    -  Battery Recharge Time: 6.5 Hours
    -  Power: 100 - 200VAC; 50/60Hz
    -  Dimensions: 7in W x 8.7in H x 6.5in D
    -  Weight: 6.95lbs (With Battery)

    Learn More
  5. Critikon Dinamap 8100
    Used

    CRITIKON DINAMAP 8100

    VITAL SIGNS MONITOR

    NIBP, SYSTOLIC, MEAN AND DIASTOLIC PRESSURE

    ADULT/PEDIATRIC

    BRIGHT DISPLAY

    DIMENSIONS:
    8.75 H x 6.65 W x 6.65 D

    WEIGHT:
    9.5 LBS.

    POWER:
    120 VAC/60 Hz
    Learn More
  6. Critikon Dinamap Xl 9340 Vital Signs Monitor
    Used

    CRITIKON DINAMAP XL 9340 VITAL SIGNS MONITOR

    FOR ADULT AND PEDIATRIC USE

    FEATURES:
    - NIBP
    - PULSE
    - TEMP
    - BRIGHT LED DISPLAY

    DIMENSIONS: 14in H x 9in W x 7.5in D
    WEIGHT: 8.60 lbs

    ACCESSORIES ARE INCLUDED, DISPOSABLES
    ARE NOT
    Learn More
  7. picture of welch allyn 53nt0-e1 vsm300 vital signs monitor
    Used

    WELCH ALLYN 53NT0-E1 VSM 300 SERIES VITAL SIGNS MONITOR WITH NIBP, NELLCO SPO2, AND SURETEMP PLUS THERMOMETRY

    FEATURES:

    -  STANDARD NONINVASIVE BLOOD PRESSURE, PULSE RATE AND MAP
    -  NELLCOR PULSE OXIMETRY AND SURETEMP PLUS THERMOMETRY
    -  SUPPORTS ADULT, PEDIATRIC AND NEONATAL PATIENTS
    -  LCD DISPLAY FACILITATES MENU NAVIGATION
    -  INCLUDES AUTOMATIC BLOOD PRESSURE MODE, PROGRAMMABLE ALARMS, BUIL-IN MEMORY AND INTUITIVE ICONS
    -  BACK-UP BATTERY

    MOBILE STAND, WALL MOUNT, IV POLE MOUNT OPTIONS AVAILABLE

    IDEAL FOR USE IN: MEDICAL/SURGICAL/PEDIATRIC/LABOR & DELIVERY FLOORS, EMERGENCY OR SPECIAL PROCEDURES DEPARTMENTS, OUTPATIENT SURGERY CENTERS AND CLINICS, URGENT CARE AND DIALYSIS CENTERS, DENTAL AND SPECIALTY PHYSICIAN OFFICES

    Learn More
  8. Welch Allyn 6200 Series Patient Monitor
    Used

    WELCH ALLYN 6200 SERIES PATIENT MONITOR
    WITH WAVEFORM DISPLAY AND ALARM CONTROLS

    FEATURES:
    - 3-Lead or 5-Lead Selectable ECG
    - Heart Rate Range: 20-250 bpm
    - Heart Rate Accuracy: ±3 bpm or ±3%, whichever is greater
    - Bandwidth: 0.5-40 Hz (monitor mode) or 0.05-100 Hz (extended mode)
    - Display Sweep Speeds: 25, 12.5 or 6.25 mm/sec
    - Noninvasive Blood Pressure
    - Systolic Measurement Range: 60-250 mmHg
    - Diastolic Measurement Range: 30-160 mmHg
    - Blood Pressure Accuracy: Meets AAMI SP10-1992 Standard
    - Operating Modes: Manual (single determination) or Automatic Mode
    - Cycle Interval Choices: 1, 3, 5, 10, 15, 30 or 60 minutes
    - Pulse Oximetry (Nellcor Puritan Bennett™)
    - Measurement Range: 40-100%
    - Accuracy: ±2 digits (no motion), ±3 digits (with motion) in the range of 0-100%
    - Pulse Rate Range: 20-250 bpm
    - Pulse Rate Accuracy: ±3 digits (no motion), ±5 digits (with motion)
    - Temperature Range: 17-50° C (62.6-122° F)
    - Accuracy: Meets ASTM Accuracy Standards
    - Probe Type: YSI Series 400 Compatible
    - Impedance Respiration
    Range: 5-100 breaths per minute
    Accuracy: ±3 breaths per minute

    GENERAL:
    - Size: 35 cm x 23 cm x 25 cm (13.8” x 9.1” x 9.8”)
    - Weight: 4.3-5.5 kg (9.5-12.1 lbs) dependent on configuration
    - Power Requirements: 120 VAC, 50/60 Hz; 240 VAC, 50/60 Hz
    - Printer: Thermal array, prints waveforms and numerical trends
    - Battery: Lead acid, rechargeable
    - Battery, RS232
    Learn More
  9. Dinamap Carescape V100 Vital Signs Monitor
    Used

    DINAMAP CARESCAPE V100 VITAL SIGNS MONITOR

    FEATURES:
    - NIBP
    - TEMP
    - SpO2 - Nellcor Oximax

    Accuracy

    The CARESCAPE V100 provides precise, accurate readings using proven DINAMAP* technology. The GE DINAMAP SuperSTAT blood pressure algorithms support speed, comfort and artifact rejection for virtually all types of patients, including neonates with very low perfusion pressures, geriatrics and hyper/hypo tensive patients. When combined with the Mobile Vitals Plus application, vital signs are transmitted to the EMR in real time, eliminating any transcription errors.

    Speed

    With non-invasive blood pressure determination times as fast as 14 seconds, and the clinical accuracy of embedded DINAMAP technology, the CARESCAPE V100 monitor delivers exceptional speed and accuracy.

    Efficiency

    The CARESCAPE V100 monitor is a two-in-one monitor — it can be used for both spot check and continuous monitoring, with continuous monitoring freeing up valuable nursing time. When combined with the Mobile Vitals Plus application, nurses spend less time in documentation and more time with their patients and families.

    Infection Prevention

    GE supports your infection prevention efforts. The monitor’s durable plastic coating is compatible with most stringent chemical hospital cleansers, and GE CRITIKON* blood pressure cuffs are disposable.

    Mobility

    Not only can it withstand the rigors of tough clinical use and cleaning, the CARESCAPE V100 monitor’s battery has a long run time – typically eight to 11 hours before requiring recharge. And if the battery is discharged, it maintains the data, and you can plug it in and continue to use the monitor. This extended battery life allows you to flexibly move the monitor from one patient room to the next for the course of a shift.

    Learn More

Grid List

Set Descending Direction

9 Item(s)